Optimal solutions for corneas with an oblate profile
When the cornea has an oblate profile, caused by the effects of surgical procedures such as penetrating keratoplasty (PKP) or DALK, and laser photoablation treatments such as PRK or LASIK, it is essential to select soft contact lenses with a flat base curve, increasing the sagittal depth in the peripheral area.
Reverse geometries feature a spherical and toric design, which provides the best corrective effect and facilitates correct lens positioning.
Selection of the carrier
In cases of oblate corneas, following refractive surgery and keratoplasty (penetrating and lamellar), the ‘reverse XPERT’ profile maximises centring and reduces the likelihood of edge lifting and visual fluctuations associated with an incorrect relationship between the lens profile and corneal morphology.
Recommended polymer: Silicone Hydrogel (SH).
Recommended polymer: Silicone Hydrogel (SH).
Choice of Test LAC
- Detect SIM-K, select the BC adding a flattening of approximately 0.30/0.40 mm to the K flat.
- Select the Spherical or Toric type based on corneal and refractive astigmatism.
- Evaluate the difference in curvature between the centre and periphery (at approximately 8/9 mm) in topography (absolute scale, axial map) to define the level of inversion on the theoretical base radius.
- Select the Total Diameter based on corneal dimensions (HVID), adding a coefficient of approximately 2.5/3 mm to the measurement taken.
Application procedures
- After 30 minutes, assess the dynamics of blinking in various gaze positions and perform the push-up test; check the coverage ratio (TD vs HVID).
- If present: dislocation, excessive movement, lifting of the edge, modify the inversion and/or peripheral alignment (Skirt: step ±100µm).
- Measure the overcorrection (OR) for the best visual acuity, then order the trial or final lens, compensating for any residual cylinder with the External Toricity module.
- Polymers: SH (Hy in relation to tearing).