Solutions for irregular corneas
RGP Advance lenses feature a multi-tangential profile, designed to conform to the shape of the ocular surface and ensure correct stability during application.
Recommended for fitting on irregular corneas (KC, DMP, PK, etc.), as they promote visual recovery and minimise high-order aberrations (HOA), Advance lenses guarantee the wearer an excellent level of comfort.
The Advance scleral lens fitting protocol is easy to interpret and supports even less experienced practitioners in selecting the ideal lens for the specific corneal problem.
Recommended for fitting on irregular corneas (KC, DMP, PK, etc.), as they promote visual recovery and minimise high-order aberrations (HOA), Advance lenses guarantee the wearer an excellent level of comfort.
The Advance scleral lens fitting protocol is easy to interpret and supports even less experienced practitioners in selecting the ideal lens for the specific corneal problem.
Application philosophy
Tangential and multicurve designs, with spherical and aspherical profiles, to manage the different requirements of corneo-scleral and scleral fitting. The diameters and dimensions of the receptive chamber allow for greater uniformity in the landing zones and correct distribution of limbal lift.
Test lens selection
The sagittal depth (SAG) value is studied for different fitting requirements. In cases of minor optical irregularities (early keratoconus, epithelial dystrophies, etc.), the use of shallower lenses allows for excellent alignment with the corneo-limbal area, while in more complex situations (advanced keratoconus, keratoplasty, etc.), deeper models are required. The criteria for selecting the first lens to be tried are indicated in the normogram.
Design and division into areas
The Advance design is divided into four areas, each identified by an acronym, as described in the diagram, which relate to the respective anatomical areas of the eye.
The ability to adjust the fit by individually modifying the alignment of each area allows different problems to be managed using a single design.
Fluoroscopic evaluation and careful analysis of the tear reserve (optical section illumination) facilitate the applicator’s reading of the fit; variations in individual parameters are expressed in units (±1), corresponding to steps of ±25µm.
The ability to adjust the fit by individually modifying the alignment of each area allows different problems to be managed using a single design.
Fluoroscopic evaluation and careful analysis of the tear reserve (optical section illumination) facilitate the applicator’s reading of the fit; variations in individual parameters are expressed in units (±1), corresponding to steps of ±25µm.