Recovery Solutions
The corneal lenses in the PK range are designed for post-operative situations characterised by significant alterations in corneal morphology, such as in the case of Penetrating Keratoplasty (PK), Lamellar Keratoplasty (LK) and Radial Keratotomy (RK).
The particular geometry of the lenses, called ‘Reverse’, has different developments chosen according to individual topographical characteristics.
The extent of the inversion, expressed in millimetres, is identified with the abbreviations PK6, PK9 and PK12.
The PK application system is structured in Trial-Set with three levels of inversion (from -0.60 to -1.20mm). This organisation allows the applicator to select the model according to the type of profile: the BC is determined on an ophthalmometric basis, while the most appropriate inversion value is defined in relation to the fluoroscopic pattern.
Types of PK
PK6
It has an ideal shape for oblate corneas, with a slight variation in shape between the central and peripheral areas; the -0.60 mm inversion on the base radius allows for easier adaptation in PK and LK keratoplasty with a more regular fit.
PK9
The model has a reversal of -0.90 mm on the BC value and represents the first application option in corneas undergoing penetrating keratoplasty (PK) with a protruding flap, where the oblate profile has a less linear and continuous fit.
PK12
Ideal in particularly irregular post-operative situations characterised by a severely oblate profile, such as radial keratotomy and PK with protruding flap. The inversion value of -1.20 mm determines a significant geometric variation that promotes positioning and stability.
Application instructions
- Post-operative situations, such as: PK, LK, RK.
- Oblate, irregular profile and fit defects
Application procedures
- Observe the topography – absolute scale, tangential map – and the profile of the cornea under biomicroscopy to assess the oblate shape and, in keratoplasty, the type of fit.
- Select a PK6 with a base radius 0.20/0.30 mm narrower than the corneal flat K parameter (SIM-K) from the set as the first trial lens.
- Assess the fluoroscopic pattern in the laf, checking the central alignment and peripheral support: if the lens is flat in one of the two sectors, select a narrower radius and/or switch to the model with greater inversion: PK9 or PK12.
- In case of partial alignment on one of the main meridians or in a specific area, consider the Internal Toric or Sector Asymmetric construction options.